PMSM Large Industrial Ceiling Fans (PMSM Direct Drive HVLS Fan)

banner
PMSM Large Industrial Ceiling Fans
Energy Saving PMSM Industrial Ceiling Fan Installed in Large Manufacturing Workshop
Direct Drive HVLS Fan Providing Wide Air Coverage in Industrial Facility
Permanent Magnet Industrial Ceiling Fan for Warehouse Ventilation and Cooling
PMSM Direct Drive HVLS Fan Reducing Heat Stress in High Temperature Workshops
Large Industrial Ceiling Fan with Permanent Magnet Motor for Energy Efficient Ventilation
PMSM Large Industrial Ceiling Fans
Energy Saving PMSM Industrial Ceiling Fan Installed in Large Manufacturing Workshop
Direct Drive HVLS Fan Providing Wide Air Coverage in Industrial Facility
Permanent Magnet Industrial Ceiling Fan for Warehouse Ventilation and Cooling
PMSM Direct Drive HVLS Fan Reducing Heat Stress in High Temperature Workshops
Large Industrial Ceiling Fan with Permanent Magnet Motor for Energy Efficient Ventilation

PMSM Large Industrial Ceiling Fans (PMSM Direct Drive HVLS Fan)

The permanent magnet industrial HVLS fan features ultra-low energy consumption and low operating costs, with a single unit covering an extensive area of up to 1,000 square meters. Operating at just 58 dB, it delivers powerful air circulation, enhances ventilation, and effectively reduces perceived body temperature, making it ideal for open or semi-open high-temperature workshop environments.

Principle Description: Through a three-dimensional breeze with an ultra-wide coverage area, it accelerates the evaporation of sweat on the human skin surface, achieving a reduction in perceived temperature of 5-8°C (even if the ambient air temperature remains unchanged). This makes it the most energy-efficient  cooling solution for high-temperature workshops.

Comparison with Traditional Air Conditioning: No enclosed space is required, nor is there a need to bear high electricity bills and installation/maintenance costs. In workshops exceeding 40°C, when the outdoor AC units shut down due to thermal protection, the permanent magnet fan still operates stably, providing life-saving wind for workers.

Installation Notes: To achieve the best results, the recommended installation height is 4-8 meters. For workshops with low ceiling heights (<4 meters), obstacles, or frequent overhead crane operations, we can provide customized short blades + safety ring solutions.

PRODUCT DETAILS

ModelDiameterVoltagePowerBladesBlade WidthMax. SpeedFrequencyAirflow Rate (m³/min)
WJ-7.37.3M220V/380V1.6KW618.5cm60RPM50HZ15500
WJ-6.16.1M220V/380V1.3KW618.5cm60RPM50HZ13500
WJ-5.55.5M220V/380V1.1KW618.5cm80RPM50HZ11500
WJ-5.05M220V/380V1.1KW615.2cm85RPM50HZ10500
WJ-4.24.2M220V750W615.2cm90RPM50HZ7200
WJ-3.63.6M220V750W615.2cm100RPM50HZ5200
WJ-3.03M220V500W615.2cm120RPM50HZ4100


  • Fan Blades

    Fan Blades

    Extruded and stretched from aluminum-manganese-magnesium alloy, featuring an airfoil internal rib reinforcement structure, it offers advantages such as high strength, excellent toughness, light weight, long service life, and operational safety. The blade surface undergoes T5+ bright anodizing treatment to enhance its corrosion and oxidation resistance, enabling it to cope with special environmental operations.Steel blades are more often used in specific industrial environments that are cost-sensitive and have low anti-corrosion requirements.

  • Tail

    Tail

    Molded from high-temperature resistant materials, the streamlined winglet design provides vortex stabilization and low noise anti-lift comfort. When the fan blades rotate, airflow generates tip vortices at the trailing edge of the airfoil blades; the winglets eliminate this energy loss, stabilizing fan operation to deliver a comprehensive 1-3 meter three-dimensional natural breeze.

  • Thickened Steel Wire Ropes

    Thickened Steel Wire Ropes

    Strengthens high-altitude protection, with each steel wire rope possessing a tensile strength of up to 1,500 kg, further upgrading anti-drop security.

  • Anti-detachment Ring

    Anti-detachment Ring

    Connects the fan blades, chassis, and motor into a single integrated unit, ensuring more stable overall operation and preventing any components from falling off.

  • Intelligent Control System

    Intelligent Control System

    IP54 protection rating, permanent magnet synchronous variable frequency technology, anti-electromagnetic interference, anti-radiation, compact size, light weight, and exquisite appearance.
    Power on, power off, acceleration, deceleration, natural breeze mode, forward/reverse rotation switching.
    The system includes built-in protections for overvoltage, undervoltage, loss of voltage regulation, overcurrent, phase loss, overload.

  • Permanent Magnet External Rotor Direct Drive Motor (PMSM Outer Rotor Direct Drive Motor)

    Permanent Magnet External Rotor Direct Drive Motor (PMSM Outer Rotor Direct Drive Motor)

    No resistance loss in the rotor windings, making it a highly efficient, energy-saving, and maintenance-free power heart. Zero rotor copper loss / High efficiency and high precision / Large power factor / Improves grid environment / Wide frequency modulation range (0-200 Hz) / Compact size and light weight / Highly energy-efficient (electricity-saving).

Q: The workshop temperature exceeds 40°C, is this Permanent Magnet Synchronous External Rotor Direct Drive HVLS Fan still useful?

A: Absolutely useful, and it might be the only affordable heat stroke prevention solution you have.

 

Principle: When the air temperature is above 35°C, the human body relies primarily on sweat evaporation for heat dissipation. The wind speed provided by the fan can increase sweat evaporation efficiency by 5 times, reducing the perceived temperature to below 32°C, effectively avoiding heatstroke.

 

Comparison: When the workshop temperature reaches 42°C, the cooling efficiency of ordinary air conditioners drops by 50% or they even shut down; evaporative air coolers (water-cooled air conditioners) will increase humidity by 90%, making people feel even more uncomfortable. Meanwhile, the permanent magnet industrial fan consumes only 1.5 kWh of electricity per hour per 1,000 square meters, running stably.

 

For clients with a higher budget, they can choose to pair air conditioning with industrial ceiling fans. The air conditioner generates cold air to cool the temperature, while the industrial ceiling fan accelerates the circulation of cold air throughout the space.